Storage of gasoline and other
flammable vapors and liquids in the
vicinity of this or any other appliance
may result in fire or explosion. Do not
store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Maintain clearance to combustibles.
Keep these instructions for future reference.
Please read and save these instructions. This heater must be installed and serviced by trained gas installation and service
personnel only! Read carefully before attempting to assemble, install, operate or maintain the product described. Protect
yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury
and/or property damage! Retain these instructions for future reference.
Form 5S5668 Printed in U.S.A.
03460
1206/346/VCPVP
Dayton Patio Heaters
®
Description
Dayton high-intensity patio heaters become highly efficient generators
of infrared radiation by heating a ceramic refractory material to
incandescence. The principal operation is to pass a gas-air mixture
through a perforated ceramic refractory, and ignite it on the refractory
surface. This causes the ceramic material to be heated to approximately
1780°F and generate large amounts of infrared radiation that may be
directed anywhere heat is desired. Infrared radiation heats people and
objects it strikes and not the intervening air. Included is a direct spark
ignition system, manifold pressure tap, porous ceramic grids, a stainless
steel housing and a preset mounting bracket for mounting the heater.
Typical applications are restaurant patios, loading docks, warehouses,
service garages, factories, aircraft hangars, etc.
Shut off gas to the appliance.
Extinguish any open flame.
Do not try to light any appliance.
Do not touch any electrical switch.
Call your gas supplier. Do not use any phone in your
building.
Follow the gas supplier’s instructions.
If you cannot reach your gas supplier,
call the fire department.
For Your Safety
If you smell gas:
WARNING
!
!
WARNING
!
!
®
Installation, Operation, Maintenance and Parts Manual
1RVT7 and 1RVT8
Improper installation, adjustment,
alteration, service or maintenance can
cause property damage, injury or death.
Read and understand the installation,
operating and maintenance instructions thoroughly
before installing or servicing this equipment.
This heater must be installed and serviced by trained
gas installation and service personnel only. Inspect the
heater annually. Failure to comply could result in
personal injury, asphyxiation, death, fire and/or
property damage.
Not for indoor residential use.
This heater is not approved for use in
any indoor residential application. This
includes, but is not limited to, attached
garages, solarium, living quarters, etc. Installation in
residential indoor spaces may result in property
damage, asphyxiation, serious injury or death.
WARNING
!
!
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - Dayton Patio Heaters

Storage of gasoline and other flammable vapors and liquids in the vicinity of this or any other appliance may result in fire or explosion. Do not store

Page 2

Dayton Installation, Operation, Maintenance and Parts ManualDayton Patio Heaters®1RVT7 and 1RVT810WARNING!Heater MountingImproper suspension of the in

Page 3 - Applications

®Dayton Installation, Operation, Maintenance and Parts Manual Models 1RVT7 and 1RVT811Chart 2.1 -

Page 4 - Clearance to Combustibles

Your patio heater is equipped with preset mounting hardware. Figures 2.6 and 2.7 illustrate various mounting configurations using the preset mounting

Page 5

®Dayton Installation, Operation, Maintenance and Parts Manual Models 1RVT7 and 1RVT813Gas SupplyW

Page 6

Dayton Installation, Operation, Maintenance and Parts ManualDayton Patio Heaters®1RVT7 and 1RVT8141. Disconnect the power to the heater.2. Turn off th

Page 7

®Dayton Installation, Operation, Maintenance and Parts Manual Models 1RVT7 and 1RVT815WARNING!!Fa

Page 8 - Installation

Dayton Installation, Operation, Maintenance and Parts ManualDayton Patio Heaters®1RVT7 and 1RVT8NOTICEWARNING!Incorrect or improper wiring may result

Page 9

®Dayton Installation, Operation, Maintenance and Parts Manual Models 1RVT7 and 1RVT81716This infr

Page 10 - Heater Mounting

Dayton Installation, Operation, Maintenance and Parts ManualDayton Patio Heaters®1RVT7 and 1RVT818Sequence of Operation: Starting Circuit: When voltag

Page 11 - Models 1RVT7 and 1RVT8

®Dayton Installation, Operation, Maintenance and Parts Manual Models 1RVT7 and 1RVT8Wiring Diagra

Page 12 - Dayton Patio Heaters

Dayton Installation, Operation, Maintenance and Parts ManualDayton Patio Heaters®1RVT7 and 1RVT8Safety . . . . . . . . . . . . . . . . . . . . . . .

Page 13 - Gas Supply

NOTICEDayton Installation, Operation, Maintenance and Parts ManualDayton Patio Heaters®1RVT7 and 1RVT8WARNING!MaintenanceAlways wear clothing that pro

Page 14

®Dayton Installation, Operation, Maintenance and Parts Manual Models 1RVT7 and 1RVT8Symptom Possi

Page 15

For Repair Parts, call 1-800-323-062024 hours a day - 365 days a yearPlease provide following information:-Model number-Serial number (if any)-Part de

Page 16 - Electrical Requirements

23®Dayton Installation, Operation, Maintenance and Parts Manual Repair Parts List for Dayton Pati

Page 17 - Ventilation

Dayton Installation, Operation, Maintenance and Parts ManualDayton Patio Heaters®1RVT7 and 1RVT8Limited WarrantyOne-Year Limited Warranty. Patio Heate

Page 18 - Operation

WARNING!!WARNING!!NOTICECAUTION!WARNING!!Caution indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate

Page 19 - Wiring Diagrams

Dayton Installation, Operation, Maintenance and Parts ManualDayton Patio Heaters®1RVT7 and 1RVT84Clearance to CombustiblesA critical safety factor to

Page 20 - Maintenance

®Dayton Installation, Operation, Maintenance and Parts Manual Models 1RVT7 and 1RVT85Chart 1.1 -

Page 21

Dayton Installation, Operation, Maintenance and Parts ManualDayton Patio Heaters®1RVT7 and 1RVT86Public Garages:The installation of this heater in pub

Page 22 - -Serial number (if any)

!CLEARANCE TO COMBUSTIBLESFIRE HAZARD. Always maintain published clearance to combustibles. In locations used for the storage of combustible materia

Page 23

InstallationWARNING!CAUTION!Dayton Installation, Operation, Maintenance and Parts ManualDayton Patio Heaters®1RVT7 and 1RVT8Read and understand, the i

Page 24

®Dayton Installation, Operation, Maintenance and Parts Manual Models 1RVT7 and 1RVT889Figure 2.1

Commentaires sur ces manuels

Pas de commentaire